产品图片
应用
应用说明HVIS 高压绝缘片用于变电站和中压开关设备中形状复杂或需要现场裁切的绝缘防护,可制作可重复拆装的接头护罩,便于检修维护。
电压
单层最高 17.5 kV;配合填充胶最高 25 kV;双层最高 36 kV
型号与规格
| 物理性能 | 试验方法 | 技术要求 |
|---|---|---|
| Tensile Strength | ASTM D638 | 12 MPa (psi) |
| Ultimate Elongation | ASTM D638 | 500% |
| Thermal Endurance | IEC 60216 | 105°C min. |
| UV Weathering (5000 hrs) | ASTM G154 | 200% |
| Tracking and Eronson Resistance | ASTM D2303 | No tracking or erossion to the top surface or flame failure after: 1 hr at 2.50 kV 1 hr at 2.75 kV 1 hr at 3.00 kV |
| Accelerate Ageing - 168 hrs at 150°C (302°F) | ASTM D2671 ASTM D638 | 12 MPa (psi) 500% |
| Electrical | Test Method | Test Requirement |
| Dielectric Strength (2.5 mm) | ASTM D149 | 16 kV/mm |
| Volume Resistance | ASTM D257 | 1E+13 Ωcm |
| Flame Retardancy | ANSI C37.20c | Pass |
| AC Withstand | IEEE Std. 4 | Up to 75 kV |
| DC Withstand | IEEE Std. 4 | Up to 144 kV |
| Impulse | IEEE Std. 4 | Up to 175 kV |
数据表
PDF
产品资料ENG_DS_EPP-4433_A